Normally Closed Air Solenoid Valve

Normally Closed Air Solenoid Valve

Normally closed air solenoid valves serve critical shut-off functions in both pneumatic and liquid systems. These versatile components provide immediate flow interruption upon power loss, ensuring operational safety across diverse industrial environments.Direct acting & pilot type 2W solenoid valves, brass body, fit air, water and oil. Complete sizes 2W025~2W500, DC12V/24V, AC110V/220V available. Factory stock, OEM support for automation, water treatment equipment.

  • Product Introduction
 
 
 
Product Introduction
2W025 -
01.

Xingchen 2W Series Normally Closed Solenoid Valve

The 2W series is a 2/2 way normally closed fluid solenoid valve with brass body. It includes direct acting and internal pilot structures, compatible with air, clean water, hydraulic oil and other media. Full sizes from small-flow 2W025 to large-bore 2W500 are available, with various thread ports and full range of DC & AC coils. Simple installation and long service life, a universal valve for pipeline on-off control.

02.
Reliable Flow Control for Dual Media Applications

 

Normally closed air solenoid valves serve critical shut-off functions in both pneumatic and liquid systems. These versatile components provide immediate flow interruption upon power loss, ensuring operational safety across diverse industrial environments.

product-661-573
 
 

 

Model Designation System

2W

025

08

AC110V

Specification Code

Orifice Size

Port Size

Standard Voltage

2W: 2-Port 2-Position

Solenoid Valve (Normally Closed)

025:2.5mm

06:G1/8

DC12V

 

040:4mm

08:G1/4

DC24V

 

160:16mm

10:G3/8

AC24V 50/60Hz

 

200:20mm

15:G1/2

AC110V 50/60Hz

 

250:25mm

20:G3/4

AC220V 50/60Hz

 

350:35mm

25:G1

AC380V 50/60Hz

 

400:40mm

35:G1 1/4

 
 

500:50mm

40:G1 1/2

 
   

50:G2

 

Technical Specifications

 

Available in eight sizes (models: 2W025-08 to 2W500-50) with flow apertures from 2.5mm to 50mm. Designed for air and water media (viscosity ≤20CST), these units feature brass bodies and nitrile rubber seals. Pressure ranges vary:

Direct-acting models: 0-0.7MPa (air/water)

Internally piloted versions: 0.1-0.5MPa (water), 0.1-0.7MPa (air)

All units withstand 1.0MPa maximum pressure and operate between -5°C to 82°C. Threaded connections range from G1/4 to G2.

 

Model

2W025-08

2W040-10

2W160-15

2W200-20

2W250-25

2W350-35

2W400-40

2W500-50

Working fluid

Air, water, oil

Action type

Direct-acting

Internally piloted

Type

Normally closed

Orifice diameter (mm)

2.5

4.0

16

20

25

35

40

50

Cv value

0.23

0.60

4.8

7.6

12

24

29

48

Port size

G1/4

G3/8

G1/2

G3/4

G1

G1 1/4

G1 1/2

G2

Applicable fluid viscosity

≤20CST

Operating pressure range

Direct-acting: 0–0.7 MPa (Water and oil: 0.1–0.5 MPa; Air: 0.1–0.7 MPa)

Max. proof pressure

1.0MPa

Fluid and ambient temperature

-5~85°C

Operating voltage range

±10%

Main component materials

Body

Brass

Seal

Nitrile rubber

Coil power

15VA

20VA

50VA

Mounting method

Horizontal mounting

 

Electrical & Efficiency Features&Core Advantages

 

  • Features pure copper coils (not brass) for 15-20% reduced power consumption. Compatible with AC/DC voltages (±10% tolerance) with power requirements spanning 15VA to 50VA. Continuous operation capability (up to 15 days with energy-saving module) exceeds standard water valve limitations.
  • Full brass valve body with reliable sealing, compatible with water, air and hydraulic oil. Complete size range with flow orifice from 2.5mm to 50mm: direct acting for small bore low pressure, pilot type for large bore high pressure. Multiple coil voltages including DC12V/24V, AC24V/110V/220V/380V. Standard normally closed design automatically cuts off fluid when power off for safe operation. Universal thread ports, direct replacement without pipeline modification for easy installation.

 

Critical Installation Requirements

 

  • Orientation: Must mount horizontally with coil vertical
  • Directional Flow: Arrow indicates media direction - reversal causes malfunction
  • Filtration: Mandatory 40μm pre-filtering for unclean media
  • Voltage Matching: Essential for proper actuation (e.g., AC220V supply requires AC220V unit)
  • Electrical Connections: Secure terminal contacts prevent operational failure

 

Performance Characteristics

 

  • Fail-Safe Design: Automatically closes during power interruption
  • Rapid Response: Immediate sealing upon de-energization
  • Low Maintenance: Resists clogging with proper filtration
  • Dual-Media Adaptability: Handles compressed air and water systems

 

Maintenance Tips

 

Install filter upstream to prevent dirt from jamming internal spool; mount valve horizontally upright, inverted installation is forbidden. Do not energize coil continuously for long hours to avoid overheating burnout. Clean pipeline impurities before long shutdown to extend seal service life. Disassemble and clean the spool if leakage occurs after valve closes.

 

Industry Applications

 

Water Systems

  • Irrigation control
  • Cooling circuit shut-off
  • Potable water distribution
  • Boiler feed lines

 

Pneumatic Systems

  • Machinery safety interlocks
  • Compressed air dump valves
  • Tooling isolation

 

Operational Advantages

 

The brass construction provides superior corrosion resistance versus aluminum alternatives, particularly in wet environments. Pure copper windings extend service life while reducing heat generation. Horizontal mounting prevents core misalignment and seal wear. For water services, the energy-saving module enables extended operation without coil burnout - a critical advantage in continuous processes. Compact G1/4 and G3/8 models suit equipment retrofit applications where space constraints exist.

 

Safety Compliance

 

Units meet international standards for:

  • Leak prevention in closed position
  • Pressure containment at 1.5× working pressure
  • Electrical insulation for wet environments
  • Temperature resilience in unregulated spaces

 

These characteristics make this product family particularly valuable for food processing plants, mobile equipment, and manufacturing facilities requiring dependable emergency shut-off capabilities across multiple fluid types.

 

Outline Dimensions (mm)

product-1155-447

 

Model

A

B

C

D

K

2W160-10

93

55.5

106.5

67.5

G3/8

2W160-15

93

55.5

106.5

67.5

G1/2

2W200-20

97

55.5

113

73

G3/4

2W250-25

102.5

72.5

121

94

G1

2W350-35

134.5

92.5

159

120

G1 1/4

2W400-40

137.5

92.5

165

122

G1 1/2

2W500-50

151.5

110

188

170

G2

 

FAQ

Q1: What fluid can 2W solenoid valve control?

A1: Air, clean water and light hydraulic oil. Not fit corrosive liquid without customized seals.

 

Q2: What's the difference between direct acting and pilot type?

A2: Small sizes (2W025/040) adopt direct acting for low pressure; large sizes from 2W160 use pilot design to support higher working pressure.

Q3: Is this valve normally open or closed?

A3: Standard 2W series is normally closed, fluid cuts off when power is off.

Q4: What coil voltages do you have?

A4: DC12V, DC24V, AC24V, AC110V, AC220V, AC380V are all in stock.

 

Hot Tags: normally closed air solenoid valve, China normally closed air solenoid valve manufacturers, suppliers, factory, air solenoid control shut off valve, 24 volt solenoid coil, air pressure solenoid, Normally Closed Air Solenoid Valve, 5 port solenoid valve, closed center pneumatic valve